Hand Held Refractometer


Product Description

Handheld Refractometers for Honey Beer Urea Brix Salt Milk

The Handheld Refractometers are specially designed for measuring the concentration of many kinds of solution listed as following: Juices, Beverages, Honey, Salt water, Brine, Cleaning fluid, battery fluid, Antifreeze and Industrial fluids etc. And they can also test for the proportion of the water-soluble solution. They can be easily used and they are competitive in price. You only need to drop some liquid on the prism and then make it towards to the sunlight. Then the reading of the concentration will appear. ATC means Automatic Temperature Compensation.

1. For Brix

ModelRangeResolutionAccuracy
RHB-80ATCBrix 0~80%0.5%±0.5%
RHB-90ATCBrix 0~90%0.5%±0.5%
RHB-90SBrix 0~42; 42~71; 71~90%0.2%±0.2%
RHB-80SBrix 0~50; 50~80%0.2%±0.2%
RHB-10ATCBrix 0~10%0.10%±0.10%
RHB-18ATCBrix 0~18%0.10%±0.10%
RHB-20ATCBrix 0~20%0.10%±0.10%
RHB-32ATCBrix 0~32%0.20%±0.20%
RHB-50ATCBrix 0~50%0.5%±0.5%
RHB-62ATCBrix 28~62%0.2%±0.2%
RHB-82ATCBrix 45~82%0.5%±0.5%

2. Beer Refractometer

ModelRangeResolutionAccuracy
AMR008Brix: 0~32%0.2%±0.2%
SG: 1.000~1.1200.001±0.001

3. Salinity Refractometer

ModelRangeResolutionAccuracy
RHSA-4ATCSalinity 0~40‰1‰±1‰
Gravity 1.000~1.0300.001±0.001
RHS-10ATCSalinity 0~100‰1‰±1‰
Gravity 1.000~1.0700.001±0.001
RHS-10BATCBrix 0~10%0.2%±0.2%
Salinity 0~100‰1‰±1‰
Gravity 1.000-1.0700.001±0.001
RHS-28ATCSalinity 0~28%0.2%±0.2%
RHS-28BATCSalinity 0~28%0.2%±0.2%
Brix: 0~32%0.2%±0.2%
RHS-35ATCSalinity 0~35%0.5%±0.5%

4. Clinical Protein Refractometer

ModelRangeResolutionAccuracy
VUR1TSerum Protein 0~12g/dl0.2±0.2
Urine Gravity 1.000~1.040sg0.002±0.002
VUR2TSerum Protein 0~12g/dl0.2±0.2
Urine Gravity 1.000~1.050sg0.002±0.002
Refractive Index1.3330~1.3600RI0.0005±0.0005
VUR3TSerum Protein 0~12g/ml0.2±0.2
Urine Gravity 1.000~1.050UG0.002±0.002
Refractive Index: 1.3330~1.3600nD0.0005±0.0005
VUR4TSerum Protein: 0~12g/dl0.2±0.2
Urine Gravity 1.000~1.040UG0.002±0.002
Refractive Index 1.3330~1.3600nD0.0005±0.0005

5. PET (CAT, DOG) Clinical Protein Refractometer

ModelRangeResolutionAccuracy
AMR016Serum Protein/Plasma: 2~14gms/100ml0.1±0.1g/dl
Cat Urine Gravity: 1.000~1.0600.001±0.001sg
Dog Urine Gravity: 1.000~1.0600.001±0.001sg

6. Automotive AdBlue / DEF Urea Concentration Test Meter

ModelRangeResolution
AMR001Urea: 0~40%0.2%
AMR002Urea: 0~40%0.2%
EG: -60°F ~ 32°F10°F
PG: -50°F ~ 0°F10°F
AMR003Urea: 0~40%0.2%
EG: -50°C ~ 0°C5°C
PG: -50°C ~ 0°C5°C
CW: -40°C ~ 0°C10°C
AMR004Urea: 30-35%0.2%
EG: -50°C ~ 0°C5°C
PG: -50°C ~ 0°C5°C
CW: -40°C ~ 0°C10°C
BF: 1.10 ~ 1.40Kg/L0.01Kg/L

7. Milk Refractometer

ModelRangeResolution
AMR005Soy Milk: 0~25%0.5%
Brix: 0~32%0.2%
AMR006Water in Milk: 0~20%0.2%

8. Battery /Antifreeze /Cleaning Fluid Refractometer

ModelRangeResolutionAccuracy
RHA-100ATCEthylene Glycol: -84°F~32°F5°F±5°F
Propylene Glycol: -60°F~32°F5°F±5°F
Battery: 1.100~1.400sg0.01sg±0.01sg
RHA-200ATCEthylene Glycol: -60°C~0°C5°C±5°C
Propylene Glycol: -50°C~0°C5°C±5°C
Battery: 1.100~1.400sg0.01sg±0.01sg
RHA-503CBattery: 1.100~1.400sg0.01sg±0.01sg
Ethylene Glycol: -50°C~0°C5°C±5°C
Propylene Glycol: -50°C~0°C5°C±5°C
Cleaner: -40°C~0°C5°C±5°C
VBC8Battert: 1.000~1.400sg0.01sg±0.01sg
Ethylene Glycol: 0%~100%5%±5%
Ethylene Glycol: -60°C~0°C5°C±5°C

9.  Brake Fluid Checker

ModelRangeResolution
VBK1DOT3: 1~6% Moisture1%
Boiling Point: 250~500°F10°F
Super DOT3: 1-6% Moisture1%
Boiling Point: 250-570°F10°F
VBK2DOT3: 1-6% Moisture1%
Boiling Point: 125-275°C5°C
Super DOT3: 1-6% Moisture1%
Boiling Point: 150-275°C5°C

10. Alcohol Refractometer

ModelRangeResolutionAccuracy
RHW-80w/w: 0-50%, 50-80%0-50%: 1%; 50-80%: 2.5%±1%

11. Refractive Index

ModelRangeResolutionAccuracy
VND1nD.1.333-1.5200.001±0.002
VND2nD.1.333-1.3800.001±0.002
VND4nD.1.435-1.5200.001±0.002

12. Bee Honey Refractometer

ModelRangeResolutionAccuracy
RHH13-25water: 13~25%0.1%±0.1%
RHH12-30water: 12~30%0.1%±0.1%
RHH-92ATCBrix: 58~92%0.5%±0.5%
Baume: 38~43Be'0.5±0.5
water: 12~27%1%±1%
RHH-90ATCBrix: 58~90%0.5%±0.5%
Baume: 38~43Be'0.5±0.5
water: 12~27%1%±1%

13. Wine Refactometer

ModelRangeResolutionAccuracy
RHW-25aATCAlcohol 0~25%VOL0.2%±0.2%
Baume 0~20'±0.2±0.2
RHW-25ATCAlcohol 0~25%0.2%±0.2%
RHW-25bATCAlcohol 0~25%VOL0.2%±0.2%
Brix 0~40%0.2%±0.2%
RHBS-32aATBrix 0~32%0.2%±0.2%
Oechsle 30~140°Oe1.0°±1.0°
RHBS-32ATCBrix 0~32%Mas Sacch0.2%±0.2%
Oechsle 0~140°Oe1.0°±1.0°
KMW 0~27° (Babo)0.2°±0.2°
RHBS-44ATCBrix 0~44%0.4%±0.4%
Oechsle: 0~190°Oe2.0°±2.0°
KMW: 0~38° (Babo)0.4°±0.4°

14. Emulsion Reractometer

ModelRangeResolutionAccuracy

M10: 0~15%0.5%±0.5%

MDT: 0-15%0.5%±0.5%

15. Contact Lens Refractometer

ModelRangeResolutionAccuracy
AMR01235~80%1%±1%

16. IPA (Iso-Propyl Alcohol)  Refractometer

ModelRangeResolutionAccuracy
AMR0150~60% (v/v)±1±1%
-23°C~0°C1°C±1°C