Atomic Absorption
Spectrophotometer (AAS) AMT3800 Serials
|
|
Features 1. Advance technologies intelligent stray light measure and correction technology 2. Automatic measurement and stray light dynamic detected without any reference materials and increment cost. It improved instrument's optical precision. Linear range and background correction effectively. 3. Original Optical Noise Reduction, it improved instrument's optical performance, linear range and enhanced background correction. 4. Developed interval lamp control technology. It makes normal hallow cathode lamps self-absorption background correction possible without and influence to instrument's stability. Meanwhile it will prolonged working like of the lamp. The cost of normal hallow cathode lamp is only about 1/10 of special lamp. |
|
|
4. Original "Hg
lamp-reagent" gradient measurement. we established an exact mathematical
model to estimate "double beam linear and balance" specification. This
technology provided a fast and economic method for instrument self
testing system. It also established a brand new method to improve
instrument's detection performance. 5. Numerous technological innovation and renewal such as fashion design, element lamp multi-dimensional automatic adjustment system, gas path electronics functional and modular design, No-adjustment D-lamp holder and so on. |
|
| Technical Specification | ||||
| Model | AMT3801AA | AMT3802AA | AMT3803AA | |
|
Optical System |
Instrument Type | Single Beam Reflection Achromatic Optics System | ||
| Mono Chromometer | Achromatic C-T ,Focus 350mm | |||
| Dispersion elements |
Grating system 1200line/mm
characterization area 40¡Á40mm2 Scintillation wavelength 250nm |
|||
| Bandwidth | 0.1,0.2,0.7,1.4mm Adjustable | |||
| Wavelength Range | 190-900 | |||
| Wavelength Accuracy | ¡À0.2 | |||
| Wavelength Repeatability | ¡Ü0.1nm | |||
| Resolution | Mn 3lines(279.5 & 279.8 Peak and Valley ¡Ü30% | |||
|
Spectrophotometric |
Measurement | A,T,C | ||
| Photometric Range | 0-125%, -0.1-3.00A | |||
| Static Baseline Drift | (Cu) ¡À0.003A/30min | |||
| Dynamic Baseline Drift | (Cu) ¡À0.006A/30min | |||
| Background Correction | D-Lamp Background Correction >50times Correction Ability (1Abs) | |||
| Atomization System | Flame | Graphite Furnace | Flame/Graphite Furnace | |
| Flame | Characteristic Concentration | (Cu)¡Ü0.025ug/ml | ---- | (Cu)¡Ü0.025ug/ml |
| Detection limit | (Cu)¡Ü0.004ug/ml | ---- | (Cu)¡Ü0.004ug/ml | |
| Precision | RSD¡Ü0.6% | ---- | RSD¡Ü0.6% | |
| Burner | titanium | ---- | titanium | |
| Nebulizer | high-efficient Nebulizer | ---- | high-efficient Nebulizer | |
| Spray chamber | anticorrosion material | ---- | anticorrosion material | |
| Safety measures | Flame fuel gas, power assisted gas abnormal pressure protection | ---- | Flame fuel gas, power assisted gas abnormal pressure protection | |
| Graphite Furnace | Characteristic quantity | ---- |
Characteristic value Cd¡Ü0.5pg Characteristic value Cu¡Ü20pg |
Characteristic value Cd¡Ü0.5pg Characteristic value Cu¡Ü20pg |
| Detection Limit | ---- | Detection limit Cd¡Ü0.8 pg | Detection limit Cd¡Ü0.8 pg | |
| Precision | ---- | Precision Cd , Cu¡Ü 4% | Precision Cd , Cu¡Ü 4% | |
| Temperature Range | ---- | Room-temperature~3000¡æ | Room-temperature~3000¡æ | |
| High-Power Heating Range | ---- | 1500¡æ¡«3000¡æ | 1500¡æ¡«3000¡æ | |
| Ramp time & Holding time | ---- | 1s¡«255s | 1s¡«255s | |
| Heating Rate | ---- | Max Heating Rate 2000¡æ/S | Max Heating Rate 2000¡æ/S | |
| Atomization Heating | ---- | Optical Control, Time Control,Normal | Optical Control, Time Control, Normal | |
| Protect Gas Flow Rate out of Graphite Tube | ---- | 1 L/min | 1 L/min | |
| Protect Gas Flow Rate in Graphite Tube | ---- | 0-50ml/min micro-flow, 300-400ml/min Fixed-Flow | 0-50ml/min micro-flow, 300-400ml/min Fixed-Flow | |
| Safety measures | ---- | Cooling water flow, Protect Gas Pressure, furnace temperature, Graphite Tube Alarm | Cooling water flow, Protect Gas Pressure, furnace temperature, Graphite Tube Alarm | |
| Data Process | Test Manner | Flame, Graphite Furnace, hydride-AA, flame emission | ||
| Concentration | standard curve, standard addition, interpolation | |||
| Times of repetitive | Measurement 1-30times, Average Value of A&C | |||
| Report Print | parameters, data result | |||
| Other | PC | exteriorization | ||
| Dimension (mm) | 790¡Á600¡Á540 | 790¡Á600¡Á540 | 790¡Á600¡Á540 x 2 | |
| Weight (kg) | 70 | 70 | 70+70 | |
| Power Supply | (220¡À22)V, (50¡À1)Hz | |||
| Temperature range | 10¡æ ~ 30¡æ | |||
| Humidity range | 40% ~ 85% | |||
Note: AMT3803AA = AMT3801AA + AMT3802AA, technical specifications, profile and configuration may changed without notice
|
Visible
Spectrophotometer AMV01
|
| Features ¡ö Large LCD screen (128x64 Dots). ¡ö Can display and save 50 groups of data, 3 groups per screen. ¡ö Data can be restored after a sudden power cut. ¡ö Auto setting wavelength. ¡ö Tungsten lamp & deuterium lamp can be turned on/off individually to extend lifetime. ¡ö Automatic WL. calibration and dark current getting. ¡ö Optional software UV-Professional can expand the applications to Kinetics and Quantitative. |
![]() |
| Optical System | Single beam, Grating 1200 lines/mm |
| Wavelength Range | 325-1000nm |
| Bandwidth | 4nm |
| Wavelength Accuracy | ¡À1nm |
| Wavelength Repeatability | 0.5nm |
| Wavelength Setting | Auto |
| Photometric Accuracy | ¡À0.5%T |
| Photometric Repeatability | 0.3%T |
| Photometric Range | -0.3-3A,0-200%T |
| Stray Light | ¡Ü0.3%T |
| Stability | ¡À 0.002A/h @ 500nm |
| Display | 128*64 Dots LCD |
| Detector | Silicon Photodiode |
| Standard Cell Holder | 4-position 10mm cell changer |
| Light Source | Tungsten Lamp |
| Output | USB Port & Parallel Port(Printer) |
| Power Requirements | AC 85~250V |
| Dimension | 420*280*180mm |
| Weight | 10kg |
|
Visible
Spectrophotometer AMV02, AMV02PC (with scan software)
|
|
¡öLow Stray Light:
The stray light is below 0.05%T.The monochromator is totally sealed and
the optical surfaces are protected with a silicon dioxide membrane. The
excellent optical system and electric circuit design ensures the very
low stray light. ¡öLarge LCD display: adopt 128*64 Dots LCD as its display system. Thus makes the results easy to read. And the Standard Curve can be displayed on it clearly, Also it can display 5 groups of data per screen. ¡öLarge Data memory space: It can store 200 groups of data and 200 standard curves at the same time. Press arrow key to scroll, easy to reload. ¡öCan upgrade to scanning model: The instrument can be controlled by our scanning software UV-Professional developed based on Windows® through the USB port. The software expands the function to Quantitative, Kinetics, Multi wavelength and Wavelength Scanning. |
![]() |
| Wavelength Range | 320-1100nm |
| Bandwidth | 2nm |
| Wavelength Accuracy | ¡À0.8nm |
| Wavelength Repeatability | 0.3nm |
| Wavelength Setting | Auto |
| Photometric Accuracy | ¡À0.3%T |
| Photometric Repeatability | 0.2%T |
| Photometric Range | -0.3-3A,0-200%T,0-9999C |
| Stability | ¡À 0.002A/h @ 500nm |
| Baseline Flatness | ¡À 0.002A/h |
| Stray Light | ¡Ü0.05%T |
| Data Output Port | USB |
| Printer Port | Parallel Port |
| Display | 128*64 Dots LCD |
| Lamps | W Lamp |
| Detector | Silicon Photodiode |
| Power Requirements | AC 220V/50Hz or 110V/60Hz |
| Dimension | 460*360*225mm |
| Weight |
18kg |
|
Visible
Spectrophotometer AMV03, AMV03PC (with scan software)
|
|
¡öLow Stray Light:
The stray light is below 0.05%T.The monochromator is totally sealed and
the optical surfaces are protected with a silicon dioxide membrane. The
excellent optical system and electric circuit design ensures the very
low stray light. ¡öLarge LCD display: adopt 128*64 Dots LCD as its display system. Thus makes the results easy to read. And the Standard Curve can be displayed on it clearly, Also it can display 5 groups of data per screen. ¡öLarge Data memory space: It can store 200 groups of data and 200 standard curves at the same time. Press arrow key to scroll, easy to reload. ¡öCan upgrade to scanning model: The instrument can be controlled by our scanning software UV-Professional developed based on Windows® through the USB port. The software expands the function to Quantitative, Kinetics, Multi wavelength and Wavelength Scanning. |
![]() |
| Wavelength Range | 320-1100nm |
| Bandwidth | 2nm |
| Wavelength Accuracy | ¡À0.5nm |
| Wavelength Repeatability | 0.2nm |
| Wavelength Setting | Auto |
| Photometric Accuracy | ¡À0.3%T |
| Photometric Repeatability | 0.2%T |
| Photometric Range | -0.3-3A,0-200%T,0-9999C |
| Stability | ¡À 0.002A/h @ 500nm |
| Baseline Flatness | ¡À 0.0015A/h |
| Stray Light | ¡Ü0.05%T |
| Data Output Port | USB |
| Printer Port | Parallel Port |
| Display | 128*64 Dots LCD |
| Lamps | W Lamp |
| Detector | Silicon Photodiode |
| Power Requirements | AC 220V/50Hz or 110V/60Hz |
| Dimension | 460*360*225mm |
| Weight | 18kg |
|
UV
Spectrophotometer Large LCD Scanning AMV05, AMV05PC (with scan software)
|
|
¡ö
The
innovative optical layout and state of art mono-chromator with high
grade blazed holographic grating ensure accuracy. Its integrated design
assures long term stability and durability. ¡ö The precisely aligned detector and quality deuterium and halogen lamps enhance the precision across the UV/vis spectrum starting from 190nm and into the near-infrared 1100nm. ¡ö Online software upgrade capability via Internet (for stand-alone models) ¡ö Full A4 print-out of graphs and tables of results with popular inexpensive printers such as HP or Epson Deskjet. ¡ö Real-time clock for date and time stamping of results ¡ö Large LCD display (320*240 Dots Matrix) |
|
| Wavelength Range | 190-1100nm |
| Bandwidth | 1.8nm |
| Wavelength Accuracy | ¡À0.5nm |
| Wavelength Repeatability | 0.3nm |
| Photometric Accuracy | ¡À0.3%T |
| Photometric Repeatability | 0.2%T |
| Photometric Range | -0.3-3A,0-200%T,0-9999C |
| Stability | ¡À 0.002A/h @ 500nm |
| Baseline Flatness | ¡À 0.002A/h |
| Noise | ¡À 0.001A/h |
| Stray Light | ¡Ü0.05%T @ 220nm,360nm |
| Data Output Port | USB |
| Printer Port | Parallel Port |
| Display | 320*240 Dots LCD |
| Lamps | D2 Lamp & W Lamp |
| Detector | Silicon Photodiode |
| Power Requirements | AC 220V/50Hz or 110V/60Hz |
| Dimension | 460*380*180mm |
| Weight | 20kg |
|
UV
Spectrophotometer Large LCD Scanning AMV06, AMV07, AMV08
|
|
¡ö
The
innovative optical layout and state of art mono-chromator with high
grade blazed holographic grating ensure accuracy. Its integrated design
assures long term stability and durability. ¡ö The precisely aligned detector and quality deuterium and halogen lamps enhance the precision across the UV/Vis spectrum starting from 190nm and into the near-infrared 1100nm. ¡ö Online software upgrade capability via Internet (for stand-alone models) ¡ö Full A4 print-out of graphs and tables of results with popular inexpensive printers such as HP or Epson Deskjet. ¡ö Real-time clock for date and time stamping of results ¡ö Large LCD display (320*240 Dots Matrix) |
|
| Model | AMV06 | AMV07 | AMV08 |
| Wavelength Range | 190-1100nm | ||
| Bandwidth | 1.8nm | 1nm | 0.5/1.0/2.0/4.0nm |
| Wavelength Accuracy | ¡À0.3nm | ||
| Wavelength Repeatability | 0.2nm | ||
| Photometric Accuracy | ¡À0.3%T | ||
| Photometric Repeatability | 0.2%T | ||
| Photometric Range | -0.3-3A,0-200%T,0-9999C | ||
| Stability | ¡À 0.002A/h @ 500nm | ||
| Baseline Flatness | ¡À 0.001A/h | ||
| Noise | ¡À 0.001A/h | ||
| Stray Light | ¡Ü0.05%T @ 220nm,360nm | ||
| Data Output Port | USB | ||
| Printer Port | Parallel Port | ||
| Display | 320*240 Dots LCD | ||
| Lamps | D2 Lamp & W Lamp | ||
| Detector | Silicon Photodiode | ||
| Power Requirements | AC 220V/50Hz or 110V/60Hz | ||
| Dimension | 625*430*206mm | ||
| Weight | 28kg | ||
|
UV
Spectrophotometer AMV09
|
|
¡ö
Large LCD screen (128x64 Dots). ¡ö Can display and save 50 groups of data, 3 groups per screen. ¡ö Data can be restored after a sudden power cut. ¡ö Auto setting wavelength. ¡ö Tungsten lamp & deuterium lamp can be turned on/off individually to extend lifetime. ¡ö Automatic WL. calibration and dark current getting. ¡ö Optional software UV-Professional can expand the applications to Kinetics and Quantitatives. |
|
| Optical System | Single beam, Grating 1200 lines/mm |
| Wavelength Range | 200-1000nm |
| Bandwidth | 4nm |
| Wavelength Accuracy | ¡À1nm |
| Wavelength Repeatability | 0.5nm |
| Wavelength Setting | Auto |
| Photometric Accuracy | ¡À0.5%T |
| Photometric Repeatability | 0.3%T |
| Photometric Range | -0.3-3A,0-200%T |
| Stray Light | ¡Ü0.3%T |
| Stability | ¡À 0.002A/h @ 500nm |
| Display | 128*64 Dots LCD |
| Detector | Silicon Photodiode |
| Standard Cell Holder | 4-position 10mm cell changer |
| Light Source | Tungsten & Deuterium lamp |
| Output | USB Port & Parallel Port(Printer) |
| Power Requirements | AC 85~250V |
| Dimension | 420*280*180mm |
| Weight | 12kg |
|
UV
Spectrophotometer AMV10, AMV10PC (with scan software)
|
|
¡ö
Large LCD screen(128x64Dots). Can display total 200 groups of data,5
groups per screen. Can display standard curve and the curve equation. ¡ö Can save 200 groups of curve equation. Convenient for check and reload. ¡ö Data can be restored after a sudden power cut. ¡ö Auto setting wavelength. Auto zero and blank. ¡ö Tungsten lamp & deuterium lamp can be turned on/off individually to extend lifetime. ¡ö The application software UV-Professional provides complete control of the spectrophotometer from a computer through the Built-in USB port. The following functions can be easily achieved: Quantitative, Kinetics, Wavelength Scan, DNA/Protein Test and Multi-wavelength Test. ¡ö The flange of the D2 lamp makes it become true Pre-aligned design makes it convenient to change lamps. ¡ö Large sample compartment, It can accommodate 5-100mm path length cuvettes with optional holders. A variety of optional accessories are under your choice. |
|
| Optical System | Single beam, Grating 1200 lines/mm |
| Wavelength Range | 190-1100nm |
| Bandwidth | 2nm |
| Wavelength Accuracy | ¡À1nm |
| Wavelength Repeatability | 0.5nm |
| Wavelength Setting | Auto |
| Photometric Accuracy | ¡À0.3%T |
| Photometric Repeatability | 0.2%T |
| Photometric Range | -0.3-3A,0-200%T,0-9999C |
| Stability | ¡À 0.002A/h @ 500nm |
| Stray Light | ¡Ü0.1%T |
| Data Output Port | USB |
| Printer Port | Parallel Port |
| Display | 128*64 Dots LCD |
| Lamps | D2 Lamp & W Lamp |
| Detector | Silicon Photodiode |
| Power Requirements | AC 220V/50Hz or 110V/60Hz |
| Dimension | 460*360*225mm |
| Weight | 18kg |
|
UV
Spectrophotometer AMV11, AMV11PC (with scan software)
|
|
¡ö
Large LCD screen(128x64Dots).Can display total 200 groups of data,5
groups per screen. Can display standard curve and the curve equation. ¡ö Can save 200 groups of curve equation. Convenient for check and reload. ¡ö Data can be restored after a sudden power cut. ¡ö Auto setting wavelength. Auto zero and blank. ¡ö Tungsten lamp & deuterium lamp can be turned on/off individually to extend lifetime. ¡ö The application software UV-Professional provides complete control of the spectrophotometer from a computer through the Built-in USB port. The following functions can be easily achieved: Quantitative, Kinetics, Wavelength Scan, DNA/Protein Test and Multi-wavelength Test. ¡ö The flange of the D2 lamp makes it become true Pre-aligned design makes it convenient to change lamps. ¡ö Large sample compartment, It can accommodate 5-100mm path length cuvettes with optional holders. A variety of optional accessories are under your choice. |
|
| Optical System | Single beam, Grating 1200 lines/mm |
| Wavelength Range | 190 ~ 1100nm |
| Bandwidth | 2nm |
| Wavelength Accuracy | ¡À0.5nm |
| Wavelength Repeatability | 0.3nm |
| Wavelength Setting | Auto |
| Photometric Accuracy | ¡À0.5%T |
| Photometric Repeatability | 0.3%T |
| Photometric Range | -0.3-3A,0-200%T,0-9999C |
| Stability | ¡À 0.002A/h @ 500nm |
| Stray Light | ¡Ü0.1%T |
| Data Output Port | USB |
| Printer Port | Parallel Port |
| Display | 128*64 Dots LCD |
| Lamps | D2 Lamp & W Lamp |
| Detector | Silicon Photodiode |
| Power Requirements | AC 220V/50Hz or 110V/60Hz |
| Dimension | 460*360*225mm |
| Weight | 18kg |
|
UV
Spectrophotometer AMV12, AMV12PC (with scan software)
|
|
¡ö
Low Stray Light:
The stray light is below 0.05%T.The monochomator is totally sealed and
the optical surfaces are protected with a silicon dioxide membrane. The
excellent optical system and electric circuit design ensures the very
low stray light. ¡ö Large LCD display: it adopt 128*64 Dots LCD as its display system. Thus makes the results easy to read. And the Standard Curve can be displayed on it clearly, Also it can display 5 groups of data per screen. ¡ö Large Data memory space: It can store 200 groups of data and 200 standard curves at the same time. Press arrow key to scroll, easy to reload. ¡ö Can upgrade to scanning model: The instrument can be controlled by the scanning software UV-Professional developed based on Windows through the USB port. The software expands the function to Quantitative, Kinetics, Multi wavelength and Wavelength Scanning. |
|
| Wavelength Range | 190-1100nm |
| Bandwidth | 2nm |
| Wavelength Accuracy | ¡À0.5nm |
| Wavelength Repeatability | 0.2nm |
| Wavelength Setting | Auto |
| Photometric Accuracy | ¡À0.3%T |
| Photometric Repeatability | 0.2%T |
| Photometric Range | -0.3-3A,0-200%T,0-9999C |
| Stability | ¡À 0.002A/h @ 500nm |
| Baseline Flatness | ¡À 0.0015A/h |
| Stray Light | ¡Ü0.05%T |
| Data Output Port | USB |
| Printer Port | Parallel Port |
| Display | 128*64 Dots LCD |
| Lamps | D2 Lamp & W Lamp |
| Detector | Silicon Photodiode |
| Power Requirements | AC 220V/50Hz or 110V/60Hz |
| Dimension | 460*360*225mm |
| Weight | 18kg |
|
Double Beam UV
Spectrophotometer AMV15
|
|
¡ö
The innovative
optical layout and state of art mono-chromator with high grade blazed
holographic grating ensure accuracy. Its integrated design assures long
term stability and durability. ¡ö The precisely aligned detector and quality deuterium and halogen lamps enhance the precision across the UV/Vis spectrum starting from 190nm and into the near-infrared 900nm. ¡ö Online software upgrade capability via Internet (for stand-alone models) ¡ö Full A4 print-out of graphs and tables of results with popular inexpensive printers such as HP or Epson Deskjet. ¡ö Real-time clock for date and time stamping of results ¡ö Large LCD display (320*240 Dots Matrix) |
|
| Wavelength Range | 190-1100nm |
| Bandwidth | 0.1/0.2/0.5/1.0/2.0/4.0nm |
| Wavelength Accuracy | ¡À0.3nm |
| Wavelength Repeatability | 0.2nm |
| Photometric Accuracy | ¡À0.3%T |
| Photometric Repeatability | 0.2%T |
| Photometric Range | -4-4A,0-200%T,0-9999C |
| Stability | ¡À 0.0004A/h @ 500nm |
| Baseline Flatness | ¡À 0.001A/h |
| Noise | ¡À 0.0004A/h |
| Stray Light | ¡Ü0.01%T @ 220nm,360nm |
| Data Output Port | USB |
| Printer Port | Parallel Port |
| Display | 320*240 Dots LCD |
| Lamps | D2 Lamp & W Lamp |
| Power Requirements | AC 220V/50Hz or 110V/60Hz |
| Dimension | 635*440*210mm |
| Weight | 30kg |
|
Double Beam UV
Spectrophotometer AMV16, AMV17, AMV18
|
|
¡ö
The innovative
optical layout and state of art mono-chromator with high grade blazed
holographic grating ensure accuracy. Its integrated design assures long
term stability and durability. ¡ö The precisely aligned detector and quality deuterium and halogen lamps enhance the precision across the UV/Vis spectrum starting from 190nm and into the near-infrared 900nm. ¡ö Online software upgrade capability via Internet (for stand-alone models) ¡ö Full A4 print-out of graphs and tables of results with popular inexpensive printers such as HP or Epson Deskjet. ¡ö Real-time clock for date and time stamping of results ¡ö Large LCD display (320*240 Dots Matrix) |
|
|
Model |
AMV16 | AMV17 | AMV18 |
| Optical System | Double Beam(1200 Lines/mm Grating) | ||
| Wavelength Range | 190-1100nm | ||
| Bandwidth | 1.8nm | 1nm | 0.5/1.0/2.0/4.0nm |
| Wavelength Accuracy | ¡À0.3nm | ||
| Wavelength Repeatability | 0.2nm | ||
| Photometric Accuracy | ¡À0.3%T | ||
| Photometric Repeatability | 0.2%T | ||
| Photometric Range | -0.3-3A,0-200%T,0-9999C | ||
| Stability | ¡À 0.001A/h @ 500nm | ||
| Baseline Flatness | ¡À 0.001A/h | ||
| Noise | ¡À 0.001A/h | ||
| Stray Light | ¡Ü0.05%T @ 220nm,360nm | ||
| Data Output Port | USB | ||
| Printer Port | Parallel Port | ||
| Display | 320*240 Dots LCD | ||
| Lamps | D2 Lamp & W Lamp | ||
| Detector | Silicon Photodiode | ||
| Power Requirements | AC 220V/50Hz or 110V/60Hz | ||
| Dimension | 625*430*206mm | ||
| Weight | 30kg | ||
|
Biophotometer AMV20
|
|
AMV20 is a new designed
model, suit for quick test of DNA, RNA and Protein. Features 1.Can measure 0.5 ~ 2ul samples. 2.Quick measure without pre-warm. 3.There is no need to dilute the samples 4.Quick Scan, you can get the scanning curve in only 0.2 seconds. 5.Long life lamps, more than 2000 hours lifetime. 6.Software comes standard with the instruments. Specifications Wavelength Range:190nm¡«850nm Wavelength Accuracy:1nm Wavelength Resolution:1nm Optical Accuracy:0.002Abs Optical Range:0.02¡«300Abs Measure Speed:2¡«5 Seconds |
|
|
Biophotometer AMV21
|
|
AMV21 is a new designed
model, suit for quick test of DNA, RNA and Protein. Features 1.Larg LCD(128*64 Dots), can display all the curves and useful information. 2.Suit for micro samples, only 20~50ul required. 3.Professional software, can achieve all the functions on PC. 4.Can save 200 groups of data and 200 groups of Curve. Specifications Wavelength Range:190-1000nm Wavelength Resolution:0.1mm Sample Volume:20¡«50¨±l Absorbance Accuracy:0.001Abs |
|
|
Biophotometer AMV22
|
|
Main Functions 1. Nucleic Acid Quantitative Mode: 1)dsDNA 2)ssDNA 3)RNA 4)Oligo DNA 5)Oligo RNA 6)Ratio calculation(A260/A280) 2. Protein Quantitative Mode: 1)Bradford Method 2)Lowry Method 3)BCA Method 4)Biuret Method 5)Colloidal Gold Method 6)UV Absorbance Method 3.Bacteria Counting Mode: Set the WL. at 600nm,then measure the Abs, apply coefficient and dilution ratio to determine the quantity of the cloned bacteria. 4.General Spectrophotometer Mode: 1)Basic Mode 2)Quantitative Mode 3)Wavelength Scan 4)Kinetics Features 1.Large LCD(320*240 Dots), can display all the curves and useful information. 2.Suit for micro samples, only 20~50ul required. 3.Professional software, can achieve all the functions on PC. Specifications Wavelength Range: 190-1000nm Wavelength Resolution: 0.1nm Sample Volume: 20~50ul Absorbance Accuracy: 0.001Abs |
|